XDS110: UART transfers corrupt the debug session

XMLWordPrintable

    • Type: Bug
    • Resolution: Cannot Reproduce
    • Priority: Medium
    • Debug and Trace
    • DBGTRC-5481
    • Show
      https://e2e.ti.com/support/tools/ccs/f/81/t/879409
    • EMU19_M08
    • EMU20_M05
    • N/A
    • Hide
      Unable to reproduce the issue observed by the customer. As the customer is using a custom board with a nest of wires connecting the XDS110 from a LaunchPad to his board, we won't be able to create the exact same setup. And that setup could very easily be electrically noisy causing the observed issues.
      Show
      Unable to reproduce the issue observed by the customer. As the customer is using a custom board with a nest of wires connecting the XDS110 from a LaunchPad to his board, we won't be able to create the exact same setup. And that setup could very easily be electrically noisy causing the observed issues.

      When customer initiates UART transmissions, the Debug session is corrupted and disconnects.

      This was verified to happen with both CCSv9.3 and CCSv8.3.

       

            Assignee:
            TI User
            Reporter:
            TI User
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved:

                Connection: Intermediate to External PROD System
                EXTSYNC-2273 - XDS110: UART transfers corrupt the ...
                SYNCHRONIZED
                • Last Sync Date: