DSP/BIOS 5.42 has compatibility issues with newer codegen

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Unresolved
    • Icon: Medium Medium
    • SYS/BIOS
    • SYSBIOS-1357
    • 5.42.02
    • Current workaround is to use older codegen versions (e.g. as recommended in the Release Notes)
    • DSP/BIOS is no longer actively developed

      We've gotten a couple E2E posts regarding the 7.4.xx codegen with DSP/BIOS 5.42.02. One has a compiler warning and the other a compiler error with building their applications (see below). Both had a working setup when using older codegen tools.

      warning #16002-D: build attribute vendor section TI missing in
      "C:/ti/ccs910/bios_5_42_02_10/packages/ti/rtdx/lib/c6000/rtdx64xplus.lib<rtd
      x_mon.o64P>": compatibility cannot be determined

      and 

      "lab01ccfg.s62", ERROR!   at line 887: [E0003] Invalid constant specification
        SWI_Obj 1, KNL_swi, 0, _function, _pri, _mailbox, _arg0, _arg1, _dorta, _Order, _filter, _maxformat, _sumformat, _avgformat, _filtmaxmult, _filtsummult, _unittype

      https://e2e.ti.com/support/tools/ccs/f/81/t/890788

      https://e2e.ti.com/support/processors/f/791/t/890751

       