Timing difference from SYSRESET as compared to a hard reset

XMLWordPrintable

    • Type: Bug
    • Resolution: Unresolved
    • Priority: Medium
    • TI Device Drivers
    • TIDRIVERS-386
    • 3.80.00
    • Hide
      CC26X2R1
      CC2652RB
      CC1352R1
      CC13xx_CC26xx
      CC1350
      CC2640R2
      CC2650
      Show
      CC26X2R1 CC2652RB CC1352R1 CC13xx_CC26xx CC1350 CC2640R2 CC2650
    • Hide
      The first RF powerup sequence from a SYSRESET shows different timing in RF driver:
      1. When Setup command completes, XOSC_HF is not switched;
      2. A subsequent 50us timeout turns out to be 4.4ms.
      Show
      The first RF powerup sequence from a SYSRESET shows different timing in RF driver: 1. When Setup command completes, XOSC_HF is not switched; 2. A subsequent 50us timeout turns out to be 4.4ms.