Type:
Bug
-
Resolution: Fixed
-
Priority:
High
-
Code Generation Tools
-
CODEGEN-1250
-
SDSCM00052752
-
-
-
Set --cinit_hold_wdt=off. This option is only needed if there is initialization. And really only needed for large initialization which might cause watchdog timer to expire before reaching main().
RTS minimizer not working with MSP option --cinit_hold_wdt=on