PRU does not issue a NOP between writing the source registers of the MAC unit and reading the result

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: Medium
    • Code Generation Tools
    • CODEGEN-1183
    • SDSCM00052212
    • PRU_2.1.0
    • PRU_2.1.2
    • The workaround is to use the --silicon_version=2 option. This option will prevent the compiler from using the hardware loop instruction.