C2000 CGT v6.4 CLA linker errors

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: Urgent
    • Code Generation Tools
    • CODEGEN-998
    • SDSCM00051235
    • C2000_6.4.0
    • C2000_6.4.1
    • Hide
      Make the following changes to the linker command file:
      1) Remove the following:
         --undef_sym=__cla_scratchpad_end
         --undef_sym=__cla_scratchpad_start
      2) Add the following:
          .scratchpad : > CLARAM1, PAGE = 1
      Show
      Make the following changes to the linker command file: 1) Remove the following:    --undef_sym=__cla_scratchpad_end    --undef_sym=__cla_scratchpad_start 2) Add the following:     .scratchpad : > CLARAM1, PAGE = 1