Due to Collisions Between Connections with Short Intervals Fairness in CMR Reports Variance is Large on Different Connection Handles

XMLWordPrintable

    • Type: Bug
    • Resolution: Unresolved
    • Priority: Urgent
    • SimpleLink Lowpower SDK F3 BLE5 Stack
    • BLE_LOKI-4328
    • BLE_LOKI_9_20_01_RC6
    • BLE_LOKI_10_10_00
    • Hide
      CC23xx
      CC27xx
      Show
      CC23xx CC27xx

      Description: The number of successful connection monitor reports vary significantly between one connection handle to another's. For example in connection handle (conn_handle 0) the number of cm reports is ~1000 , while in (conn_handle 3) the number of cm reports is ~50 . 

      The fairness on cm reports issue is solved when we change connection interval to 100 milliseconds, and in general fairness issue not reproduce from connection interval of ~75 and above.

            Assignee:
            TI User
            Reporter:
            TI User
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:

                Connection: Intermediate to External PROD System
                EXTSYNC-6816 - Due to Collisions Between Connectio...
                SYNCHRONIZED
                • Last Sync Date: