      Description: The problem occurs when the key node device is places about 7-9 meters away in a NLOS environment. I have seen the problem reproduce at closer distances than this. The reproduction seems to occur after a CS termination event, either sent from the initiator or the reflector. 

      After the CS termination event, the application will attempt to restart the CS procedure. On the sniffer, it seems like the device is successfully restarting CS. There are a CS request, response and indication, but after the indication, there is no channel sounding after. Problem seen on 9.14.01.16 SDK.