Wrong Result Format due to Memory Corruption when using Channel Sounding Repeat Procedures

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: Urgent
    • SimpleLink Lowpower SDK F3 BLE5 Stack
    • BLE_LOKI-3723
    • BLE_LOKI_9_14_00_RC9
    • Hide
      BLE_LOKI_9_14_00_RC13
      BLE_LOKI_9_14_00
      BLE_LOKI_9_14_00_RC16
      BLE_LOKI_9_14_00_RC15
      Show
      BLE_LOKI_9_14_00_RC13 BLE_LOKI_9_14_00 BLE_LOKI_9_14_00_RC16 BLE_LOKI_9_14_00_RC15
    • CC27xx

      Description: Establishing a connection and executing the Channel Sounding with procedure repetitions between CC2745R10Q1(car) to the CC2745R10Q1/CC2340R53(key) device.

      When running the CS procedure with varying max_procedure_count values in loops, the system occasionally fails to return the last X distance results, a garbage value is returned: 4294967295. This issue occurs with no event indicating the procedure has aborted.