Can: No validation check in configurator if HOH is greater than 64

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: Medium
    • MCAL
    • MCAL-27104
    • NA
    • MCAL_SitaraMPU_10.00.00
    • Hide
      MCAL_SitaraMPU_11.00.00
      MCUSW_J7_11.00.00
      Show
      MCAL_SitaraMPU_11.00.00 MCUSW_J7_11.00.00
    • Hide
      am275x-evm
      am62a-evm
      am62d-evm
      am62x-evm
      j721e-evm
      j721s2-evm
      j722s-evm
      j742s2-evm
      j784s4-evm
      Show
      am275x-evm am62a-evm am62d-evm am62x-evm j721e-evm j721s2-evm j722s-evm j742s2-evm j784s4-evm

      CAN configurator is not reporting an error if CanHwObjectCount > 1(FIFO) and the total count is > 64.There is no validation check to report error in this scenario

            Assignee:
            TI User
            Reporter:
            TI User
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved:

                Connection: Intermediate to External PROD System
                EXTSYNC-5314 - Can: No validation check in configu...
                SYNCHRONIZED
                • Last Sync Date: