CC2340R53 Coded PHY Links terminate when more than 8 connections and switching connection PHY between coded to 1M/2M PHY`s

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: Urgent
    • SimpleLink Lowpower SDK F3 BLE5 Stack
    • BLE_LOKI-2511
    • BLE Stack BLE5-3.3.2 RC13
    • Hide
      BLE_LOKI_8_40_00
      BLE_LOKI_8_40_00_RC6
      Show
      BLE_LOKI_8_40_00 BLE_LOKI_8_40_00_RC6
    • CC23XX

      Description: CC2340R53 coded PHY connection link terminates when holding more than 8 multiple connections and switching connection PHY between coded to 1M/2M PHY`s. This issue does not occur with 8 connections on CC2340R5 device (completed several iterations of changing PHY`s between 1M/2M/Coded). This issue does not occur with 16 connections on CC2340R53 device when switching PHY`s between 1M and 2M - without Coded PHY.