RM/RM Safety Checker - User Guide HSDIV Documentation Update

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: Medium
    • PDK
    • PDK-14751
    • PROCESSOR_SDK_09.02.00
    • PROCESSOR_SDK_10.00.00
    • j784s4-evm

      Description
      In RM/PM Safety Checker User Guide Section 7, the HSDIV documentation did not align with TRM. As per the TRM, HSDIV0 is not connected to anything on the J784S4 device. But safety checkers still verify the HSDIV0 related registers.

      Resolution
      Update the PLL Safety Checkers without the reserved HSDIVs