J721S2: Master Firewall Ids Incorrect in Header file

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: High
    • PDK
    • PDK-12859
    • None
    • PROCESSOR_SDK_08.06.00
    • PROCESSOR_SDK_09.00.00
    • j721s2-evm

      Issue Description:
      J721S2 firewall ids are incorrect:
      #define CSL_MSTR_FW_A72SS0_CPU_0_CPU_0_MSMC_ID (18014398508351744U)
      #define CSL_MSTR_FW_COMPUTE_CLUSTER0_C71SS0_0_CPU_4_CPU_4_MSMC_ID (18014398508351752U)
      #define CSL_MSTR_FW_COMPUTE_CLUSTER0_C71SS1_0_CPU_5_CPU_5_MSMC_ID (18014398508351754U)
      #define CSL_MSTR_FW_COMPUTE_CLUSTER0_DRU_DRU_0_MSMC_ID (18014398508351772U)

      Based on ti.com, and other devices believe these should read as below:

      #define CSL_MSTR_FW_A72SS0_CPU_0_CPU_0_MSMC_ID (257)
      #define CSL_MSTR_FW_COMPUTE_CLUSTER0_C71SS0_0_CPU_4_CPU_4_MSMC_ID (265)
      #define CSL_MSTR_FW_COMPUTE_CLUSTER0_C71SS1_0_CPU_5_CPU_5_MSMC_ID (267)
      #define CSL_MSTR_FW_COMPUTE_CLUSTER0_DRU_DRU_0_MSMC_ID (284)

      Resolution Description:

      Fixed Firewall CSLR for J721S2