Bug
-
Resolution: Fixed
-
High
-
SimpleLink CC13x2-26x2 SDK BLE5 Stack
-
BLE_AGAMA-3862
-
-
-
CC26X2R1
Platform: Custom HW with CC2642R-Q1
SDK: 4.40
Role: Central + Broadcaster
Issue:
During an extended test where the mobile phone is walking in and out of range of the TI device, a corruption of the devices TX queue occurs leading to an unresponsive stack but functional RTOS.
Reproducibility: Currently only seen on custom HW and occurs maybe once every 3-4 days and is not reproducible on TI HW.