Uploaded image for project: 'Embedded Software & Tools'
  1. Embedded Software & Tools
  2. EXT_EP-10846

Stack TX queue becomes corrupted in very rare instance and stack becomes unresponsive during GATT write char operation

XMLWordPrintable

    • Icon: Bug Bug
    • Resolution: Fixed
    • Icon: High High
    • SimpleLink CC13x2-26x2 SDK BLE5 Stack
    • BLE_AGAMA-3862
    • Hide
      BLE Stack BLE5-2.2.6
      BLE Stack BLE5-2.2.0
      Show
      BLE Stack BLE5-2.2.6 BLE Stack BLE5-2.2.0
    • Hide
      BLE Stack BLE5-2.2.8
      BLE Stack BLE5-2.2.8 RC1
      Show
      BLE Stack BLE5-2.2.8 BLE Stack BLE5-2.2.8 RC1
    • CC26X2R1

      Platform: Custom HW with CC2642R-Q1
      SDK: 4.40
      Role: Central + Broadcaster

      Issue:
      During an extended test where the mobile phone is walking in and out of range of the TI device, a corruption of the devices TX queue occurs leading to an unresponsive stack but functional RTOS.

      Reproducibility: Currently only seen on custom HW and occurs maybe once every 3-4 days and is not reproducible on TI HW.

            syncuser TI User
            syncuser TI User
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved: