UART baud rate and operational mode condition misalignment

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: Medium
    • SITSW-4748
    • 09.02.01
    • 11.00.00
    • am62xx-sk

      On AM64x, the following combination causes no issues:

      clock frequency = 192 MHz

      baud rate = 1333333

      operational mode = 16x 

      AM64x SysConfig diagram:

      On AM62x, the same exact combination causes SysConfig to throw exceptions.

      AM62x SysConfig diagram:

      Probable Fix/Solution:

      Let us align with same conditions on both AM64x and AM62x UART SysConfig configurations. Customer has successfully been able to run clock freq = 192 MHz, operational mode = 16x and baud rate = 1333333 on Linux. So it should be fine for RTOS as well.