Flash Close Logic Requires OSPI Handle to be reset to 1S-1S-1S

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: Medium
    • SITSW-9768
    • 11.02.00
    • 12.00.00
    • Hide
      am62xx-sk
      am62xx-sk-lp
      am62x-sip-sk
      am62a-sk
      am62p-sk
      am62d-evm
      am275x-evm
      am62l-evm
      Show
      am62xx-sk am62xx-sk-lp am62x-sip-sk am62a-sk am62p-sk am62d-evm am275x-evm am62l-evm

      Currently in the API implementation of Flash_norOspiClose, the Flash gets reset to 1S-1S-1S, but before calling the Flash_norOspiWaitReady, the OSPI Handle is not reset to 1S-1S-1S. This needs to be done to make sure the Flash is closed correctly.