eMMC PHY Tuning Status Result Ignored when switching to HS400 Mode

XMLWordPrintable

    • Type: Bug
    • Resolution: Fixed
    • Priority: Medium
    • SITSW-7957
    • Hide
      10.01.00
      11.00.00
      11.01.00
      Show
      10.01.00 11.00.00 11.01.00
    • 11.02.00
    • am62p-sk

      There are several instances in the error checking and handling code inside MMCSD_xferStatusPollingFxn() where "error interrupt bits" are accessed in the MMC_CTLCFG_NORMAL_INTR_STS register (rather than in the MMC_CTLCFG_ERROR_INTR_STS register, basically mixing up bit definitions and register names. This results in error bits not getting cleared as intended.