AM62A : Reset Isolation sequence is wrong

XMLWordPrintable

    • Type: Bug
    • Resolution: Unresolved
    • Priority: Medium
    • SITSW-7624
    • 11.00.00
    • 11.02.00
    • am62a-sk

      During the Reset Processing the ISR routine, we need to disable the MCU2MAIN bridge.
      But this is not happening due to wrong Macro selection.
      And one more thing, the AM62X and AM62A have the same code.
      For the AM62X we need to restore the MAIN2MCU and MCU2MAIN bridges.
      But, the current implementation is missing steps for restoring the MCU2MAIN Bridge to AM62X.
      For the AM62A, we need to restore the MCU2MAIN bridge. Instead of this, we are using the MAIN2MCU bridge.

            Assignee:
            TI User
            Reporter:
            TI User
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:

                Connection: Intermediate to External PROD System
                EXTSYNC-5729 - AM62A : Reset Isolation sequence is...
                SYNCHRONIZED
                • Last Sync Date: