Uploaded image for project: 'Embedded Software & Tools'
  1. Embedded Software & Tools
  2. EXT_EP-9792

EMACMSP432E4 driver missing check in interrupt service routine for duplex change

    XMLWordPrintable

Details

    • Bug
    • Status: Fixed
    • High
    • Resolution: Fixed
    • TI Device Drivers
    • TIDRIVERS-4235
    • 3.00.00
    • TIDRIVERS_5_20_00
    • MSP432E4

    Description

      In the EMAC PHY interrupt service routine, EMACMSP432E4_processPhyInterrupt, reads the interrupt status register and then should be checking for duplex, but there's an error so it's actually checking for speed twice instead of speed and duplex.